- Max. output-voltage of AC hipot testing : 5kV/100mA (500VA)
- Measurement range of insulation resistance testing : 0.001MΩ to 100.0GΩ
- Electrical breakdown inspection setting available
- LAN/USB/RS232C standard digital interface
- Easy to read LCD display for real time monitoring during tests.
All measurement values and standard outlines displayed in each test
- High-voltage scanner for TOS9300 series multi-channel testing systems
- High voltage scanner can distribute the output from the test equipment by itself
- Can be connected to our conventional TOS5300 series voltage/insulation resistance testers.
- The PWM amp system provides highly-stable output
- Max. output-voltage of AC hipot testing : 5kV/100mA(500VA)
- Measurement range of insulation resistance testing : 25V to 1000V(7 steps), 500V or greater, up to 5.00GΩ Insulation Resistance test
- High-precision measurement ±1.5% of reading
- Rise/Fall time control function
- The Keylock function & the Protection cover for the front panel operation
- Equipped with USB / RS232C interface
- The PWM amp system provides highly-stable output
- Max. output-voltage of AC hipot testing : 5kV/100mA(500VA)
- Max. output-voltage of DC hipot testing : 6kV / Max. output 50W
- High-precision measurement ±1.5% of reading
- Rise/Fall time control function
- The Keylock function & the Protection cover for the front panel operation
- Equipped with USB / RS232C interface
- Complies with various safety standards
- AC/DC output (0 kV to 10 kV)
- Large color display
- Digital voltmeter and ammeter
- Digital timer
- Window comparator type employed for PASS/FAIL judgement
- Equipped with remote control function
- Various signal outputs
- Automatic discharge function (during DC operation)
- Provided with zero turn-on switch
- Compact size
- Hipot (Withstanding voltage): AC 5 kV/100 mA
- High-precision measurement ± 1.5 % of reading
- Rise/Fall time control function
- Key lock function and Protection cover on the panel operation
- Limit voltage function
- Monitoring output voltage function
- Equipped with USB and RS232C interface as standard
- Test current value: 6 A to 60 A AC / Resistance value: 0.001 Ω to 0.600 Ω
- Voltage drop-based judgment function
- Offset cancelling function
- Stores 100 test conditions in memory
- Incorporates test conditions into program
- Contact check function
- Equipped with standard GPIB and RS232C interfaces
- Equipped with standard test lead (TL12-TOS)
- Test current value: 3 A to 30 A AC / Resistance value: 0.001 Ω to 1.200 Ω
- Offset cancelling function
- Stores 100 test conditions in memory
- Incorporates test conditions into program
- Contact check function
- Equipped with standard GPIB and RS232C interfaces
- GPIB, RS232C standard equipment
- Equipped with standard test lead (TL11-TOS)
- Output voltage setting range: -25 to -1000V
- Resistance measurement range: 0.01MΩ to 5000MΩ
- Provided with the discharge function
- Equipped with the window comparato
- Hold function
- Provided with the timer function
- Rear output terminals
- Measured-value monitoring terminals
- Equipped with the panel memory
- Equipped with the SIGNAL I/O connector and remote control terminal
- Equipped with the RS232C interface as standard
- Capable of setting within the range of 50Vdc to 2000Vdc (resolution 1V)
- Ability to switch the applied voltage polarity instantly by the switch on the front panel
- The output is floating from the ground potential.
- Capable of measuring the current value between measurement points.
- Capable of measuring leakage current in three modes
- Eight built-in measurement circuit networks
- Up to 30 mA for RMS measurement
- Easy-to-understand operation
- Enables the continuous execution of tests
- Capable of saving test results
- 51 types of standard test conditions are preset
- Lets you manage the calibration time limit
- USB interface provided as standard